Appendix A
Specifications
A-6
ni.com
Environment
The NI PCI-7390
is intended for indoor use only.
Operating temperature ............................0 °C to 55 °C
Storage temperature ................................–20 °C to 70 °C
Relative humidity ...................................10% to 90%, noncondensing
Pollution Degree .....................................2
Approved at altitudes up to 2,000 m.
Compliance and Certifications
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1
•
CAN/CSA-C22.2 No. 61010-1
Note
For UL and other safety certifications, refer to the product label or visit
ni.com/certification
, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic Compatibility
Emissions................................................EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity ................................................EN 61326:1997 + A2:2001,
Table 1
CE, C-Tick, and FCC Part 15 (Class A) Compliant
Note
For EMC compliance, operate this device with shielded cabling.