N36100 will adjust the output voltage and output current according to the load
condition. Once the external load exceeds the set range of N36100, N36100 output
will maintain at the maximum set value (see below figure).
Figure 24 CP Mode
7.6 APG Analog Programming (Optional)
Steps to enter
APG
:
Press
Menu
button→ Select
APG
by rotating
→ Press
Enter
button.
Analog programming (APG) can control the output voltage by using voltage analog
signal. Users can use analog devices to set the output voltage of N36100 through the
PROG-Interface at rear panel. The analog programming signal is introduced by Pin 7
and Pin 8 at the programming interface. Pin 7 is the negative polarity of the voltage
programming input. Pin 8 is the positive polarity of the voltage programming input.
Please refer to pin definition for programming interface.
Figure 25 Programming Interface
Table 16
Number
Pin
Definition
1
GND
Digital ground
2
I_MO
Current monitoring output
3
GND
Digital ground
Note: To exit from
CP
mode, please press
Menu
button or the function button
required.