Alarms
Reference Manual for EL470 IP Satellite Modem
6 ALARMS
Alarm Types
•
Active alarm
: alarm that is present at the time when you read the alarm.
•
Memorised alarm
: alarm that has happened in the past but has been resolved
before you read the alarm (in case of intermittent alarms or a setting that has
been corrected since). The purpose of this type of alarm is to warn you that
there has been an alarm in the past but that the alarm condition is currently not
present.
•
Alarm counter
: the number of times an alarm occurred. This counter can
record up to a maximum of 255 events.
Alarm Commands
Special Command
AlAlarmsCur
Current alarm status
string
Alarm status string
Location
/Config
Description
Readout of the concatenated string of all individual alarm status replies of
the device.
A get request returns the current alarm buffer contents. The buffer is not
reset.
A set command returns the current alarm buffer contents and resets the
buffer.
RMCP
Command
CAs
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01AlarmEntry
Command
ntcDevsMod01AlAlarmsCur
OID
1.3.6.1.4.1.5835.3.1.2.1.9.0.1
Get Command Arguments
Set Command Arguments
Command(s) / Variable(s)
Page
Command(s) / Variable(s) Page
none
none
none
none
Get Reply Values
Set Reply Values
Command(s) / Variable(s)
Page
Command(s) / Variable(s) Page
version 3.1
246