Modem
Reference Manual for EL470 IP Satellite Modem
Command
IfGBSSettingsCRC
CRC
CRC
Used as
variable of
Command(s)
Page
Description
Configuration of the CRC calculation in case of XPE encapsulation or
decapsulation:
•
Enabled
: CRC calculation is used.
•
Disabled
: No CRC calculation is used.Remark: When CRC
calculation is disabled, the CRC is not send over the link.
RMCP
Command
IGc
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01InterfaceEntry
Command
ntcDevsMod01IfGBSSettingsCRC
OID
1.3.6.1.4.1.5835.3.1.4.1.92.1.1
Values
Factory Default
disabled
Enumeration
Value
Enabled
Disabled
0
1
Command
IfGSESettingsDestMac
Air-MAC (6 byte label)
mode
Air-MAC (6 byte labe
Used as
variable of
Command(s)
Page
Description
GSE encapsulation label type mode:
•
Air-MAC (6 byte label) enabled
•
Air-MAC (6 byte label) disabled
RMCP
Command
gsl
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01InterfaceEntry
Command
ntcDevsMod01IfGSESettingsDestMac
OID
1.3.6.1.4.1.5835.3.1.4.1.275.1.1
Values
Factory Default
disabled
Enumeration
Value
Disabled
Enabled
0
1
Command
IfStrConfigStreamId
Stream Id
Stream Id
Used as
variable of
Command(s)
Page
Description
Configuration of the stream index for DVB-S2 stream configurations. This
is not the input stream identifier but the array index number used for
reference in the filter configurations.
RMCP
Command
ISi
Access
Normal user : RW
Expert user : RW
version 3.1