Unit Menu
Reference Manual for EL470 IP Satellite Modem
/Unit/Monitor
Command
SyIntTemp
Device internal
temperature
Device temperature
Location
/Unit/Monitor
Description
Readout of the internal temperature of the device. The internal
temperature must be 10 and +70° C. Typically, this temperature
should be around 40°C (± 10°C).
RMCP
Command
Sst
Access
Normal user : R
Expert user : R
SNMP
Table
ntcDevsMod01SystemEntry
Command
ntcDevsMod01SyIntTemp
OID
1.3.6.1.4.1.5835.3.1.1.1.39.0.1
Values
GUI Unit
C
Cmd Unit
Factory Default (CU)
C
40
Expert Range (CU)
0 .. 100
Command
SyDevPowP3V3
3V3 power
supply
+3V3 power supply
Location
/Unit/Monitor
Description
Readout of the +3.3 volt power supply monitor. A power supply alarm is
triggered when this voltage is outside the range of +2.5 volt and +4.1 volt.
RMCP
Command
P33
Access
Normal user : R
Expert user : R
SNMP
Table
ntcDevsMod01SystemEntry
Command
ntcDevsMod01SyDevPowP3V3
OID
1.3.6.1.4.1.5835.3.1.1.1.23.0.1
Values
GUI Unit
V
Cmd Unit
Factory Default (CU)
V
3.3
Expert Range (CU)
0 .. 10
Command
SyDevPowP5V
5V power
supply
+5V power supply
Location
/Unit/Monitor
Description
Readout of the +5 volt power supply monitor. A power supply alarm is
triggered when this voltage is outside the range of +4.0 volt and +5.9 volt.
RMCP
Command
P50
Access
Normal user : R
Expert user : R
SNMP
Table
ntcDevsMod01SystemEntry
Command
ntcDevsMod01SyDevPowP5V
OID
1.3.6.1.4.1.5835.3.1.1.1.24.0.1
Values
GUI Unit
V
Cmd Unit
Factory Default (CU)
V
5
Expert Range (CU)
0 .. 10
version 3.1
31
SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS