Unit Menu
Reference Manual for EL470 IP Satellite Modem
Command
SyDevUptime
System uptime
System uptime
Values
Factory Default
String Description
length : 0 .. 128
format : any chars
/Unit/Setup/Serial port settings
Command
SyDevSerIfType
Serial M&C interface
type
Serial interf. type
Location
/Unit/Setup/Serial port settings
Description
Configuration of the monitoring and control serial port interface type:
RS485 (default) or RS232.
RS232 is used for monitoring and control of a single device.
RS485 is typically used for multiple devices on a single bus.
RMCP
Command
SIT
Access
Normal user : no access
Expert user : RW
SNMP
Table
ntcDevsMod01SystemEntry
Command
ntcDevsMod01SyDevSerIfType
OID
1.3.6.1.4.1.5835.3.1.1.1.29.0.1
Values
Factory Default
rs485
Enumeration
Value
RS485
RS232
0
1
Command
SyDevRs485Addr
Device address for
serial interface
Device RMCP address
Location
/Unit/Setup/Serial port settings
Description
Configuration of the device address for the serial interface. The device
address, used in the messages for remote serial management and control,
is a single byte with a value in the range 49 (31 hex - ASCII "1") up to 110
(6E hex - ASCII "n"). It identifies the device that has to handle the
message from the remote control unit.
When the multi-user RS485 bus is used, each device on the bus must
have a different address, unique in the system.
Address 111 (6F hex - ASCII "o") is the "broadcast" address. This can be
used when only one device is connected to a COM-port of a PC to
address the device without knowing its exact address.
RMCP
Command
Adr
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01SystemEntry
Command
ntcDevsMod01SyDevRs485Addr
OID
1.3.6.1.4.1.5835.3.1.1.1.27.0.1
Values
GUI Unit
NA
Cmd Unit
Factory Default (CU)
NA
50
Expert Range (CU)
49 .. 110
version 3.1
14