Modem
Reference Manual for EL470 IP Satellite Modem
Command
IfDvbs2BboeTxUdpPort
S2BBFoE tx UDP port
S2BBFoE tx UDP port
Location
/Modem/Control/Interfaces/Ethernet/IP termination/ntS2BBF over IP
Description
Configuration of the UDP port number to which DVB-S2 baseband frames
will be transmitted over the Ethernet interface.
RMCP
Command
btU
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01InterfaceEntry
Command
ntcDevsMod01IfDvbs2BboeTxUdpPort
OID
1.3.6.1.4.1.5835.3.1.4.1.229.1.1
Values
GUI Unit
NA
Cmd Unit
Factory Default (CU)
NA
12345
Expert Range (CU)
0 .. 65535
Command
IfDvbs2BbRxEncaps
Timetick
Encapsulation timetick Encapsulation timeti
Location
/Modem/Control/Interfaces/Ethernet/IP termination/ntS2BBF over IP
Description
This timetick defines the periodic interval for the encapsulation of
baseband frames.
RMCP
Command
brt
Access
Normal user :
no access
Expert user : RW
SNMP
Table
ntcDevsMod01InterfaceEntry
Command
ntcDevsMod01IfDvbs2BbRxEncapsTimetick
OID
1.3.6.1.4.1.5835.3.1.4.1.124.1.1
Values
GUI Unit
ms
Cmd Unit
Factory Default (CU)
ms
30
Expert Range (CU)
5 .. 999
Command
IfDvbs2BbRxBuff
HeadroomMs
Buffer headroom
Buffer headroom
Location
/Modem/Control/Interfaces/Ethernet/IP termination/ntS2BBF over IP
Description
The ntS2BBF receiver sends periodically volume requests to an external
encapsulator. To avoid that the modulator buffer would be empty, we try to
make sure that we always have a given headroom of bytes in this buffer.
This modulator buffer headroom can be configured in milliseconds.
RMCP
Command
brh
Access
Normal user :
no access
Expert user : RW
SNMP
Table
ntcDevsMod01InterfaceEntry
Command
ntcDevsMod01IfDvbs2BbRxBuffHeadroomMs
OID
1.3.6.1.4.1.5835.3.1.4.1.203.1.1
Values
GUI Unit
ms
Cmd Unit
Factory Default (CU)
ms
10
Expert Range (CU)
0 .. 5000
version 3.1
70
SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS