Unit Menu
Reference Manual for EL470 IP Satellite Modem
Command
ODCurLimits
Outdoor current limit
Outdoor cur. limit %
Location
/Unit/Control
Description
Configuration of the current limitation for the outdoor unit. If the current to
the outdoor unit exceeds the limitation an alarm is generated.
RMCP
Command
Ocl
array : [1 .. 2]
Access
Normal user :
no access
Expert user : RW
SNMP
Table
ntcDevsMod01ODUExtEntry
Command
ntcDevsMod01ODCurLimits
OID
1.3.6.1.4.1.5835.3.1.14000.1.5.1.1.[1 .. 2]
Values
GUI Unit
mA
Cmd Unit
Factory Default (CU)
mA
0
Expert Range (CU)
0 .. 4000
Command
MoODU100
ODU 100 MHz
reference
ODU 100 MHz referenc
Location
/Unit/Control
Description
Configuration command to control the 100 MHz outdoor unit reference
signal when an outdoor unit conditioning module is used. This 100 MHz
reference signal is needed whenever a Newtec outdoor unit is used and is
used as a reference for the local oscillator of the up-converter.
RMCP
Command
XOm
Access
Normal user : RW
Expert user : RW
SNMP
Table
ntcDevsMod01ODUEntry
Command
ntcDevsMod01MoODU100
OID
1.3.6.1.4.1.5835.3.1.14.1.12.1.1
Values
Factory Default
disabled
Enumeration
Value
Disabled
Enabled
0
1
/Unit/Control/AES
Command
AESGroupKey
Group Key
Group Key
Location
/Unit/Control/AES
Description
This key is used for AES decryption of encrypted keys entered by the
user.The length of the key can be 64bits or 128bits long depending on
AES key length
The value is entered as a hexadecimal value:
•
64 bits - 8 bytes (16 text bytes)
•
128 bits - 16 bytes (32 text bytes)
RMCP
Command
AGk
Access
Normal user : no access
Expert user : RW
SNMP
Table
ntcDevsMod01SystemEntry
version 3.1
29