The power supply system should be used independently as much as possible and effective
measures of preventing electric grid from interference should be adopted.
z
Ensure a good power grounding effect of equipment or add a lightning protector.
1.2.6
Other Facilities
Rack/Workbench
MX8 can be placed on a clean and flat workbench. Ensure that the workbench is stable and well
ventilated.
MX51, MX100-AG and MX120 are designed to be installed in a standard 19-inch rack, which should
provide adequate air-flow to cool down the gateway, and should be firm enough to support the weight
of the gateway. It is also recommended the rack is earth grounded properly.
PSTN Line
If the gateway is equipped with FXO interface, be sure to subscribe PSTN lines from local telephone
company and activate the lines prior to the installation.
IP Network
The gateway is connected to IP network through its 10/100 base-T Ethernet port and communicate
with other equipments through the network. Inspect IP network on the site, including router, switch,
cable wiring and etc, and make sure they are ready for the gateway.
AC Power Outlets
The gateway needs AC power supply, and sometimes the power is provided through a power strip
with extension cord. Verify that each socket outlet on the power strip is equipped with protective earth
contact and the protective action is not negated by using extension power cord.
1.3
Opening Inspection
After the completion of installation preparation, you should open the box for inspection. Make sure the
gateway and all in-box accessories match the description below.
A standard configuration of MX8 is shipped with parts listed in Table 1-3.
Table 1-3 Standard Configuration of MX8
Part Name
Quantity
Unit
MX8 Gateway
1
Set
Power Cord, AC250V/10A
1
Set
An MX51 with basic configuration should include components as shown in Table 1-4.
Table 1-4 Standard Configuration of MX51
Part Name
Quantity
Unit
MX51 Gateway
1
Set
Power Cord, 3 Meters, AC250V/10A
1
Set
Rack Mounting Kits
1
Set
An MX100-AG with basic configuration should include components as shown in Table 1-5.
Table 1-5 Standard Configuration of MX100-AG
Part Name
Quantity
Unit
MX100-AG Gateway
1
Set
Power Cord, 3 Meters, AC250V/10A
1
Set
Rack Mounting Kits
1
Set
Analog Line Cable, 3 Meters, 25 Pairs
1 or 2
Set