- 8 -
6. Installation
and
Wiring
6-1 How to Install the Indicator and Alarm Unit
The equipment can be hang on the wall or embedded.
(1) How to install on the wall
①
Make holes on the wall as shown in Fig. 6
②
If the equipment has a backup power source, attach two mounting plates on the top and bottom of the
equipment.
③
Align the anchors with the holes then insert a bolt in the upper hole.
④
Insert it in the hole on top of the equipment, insert the other bolt in the bottom hole, then tighten both bolts.
The indicator and alarm unit is not an explosion-proof construction. Install it in a non-hazardous area.
WARNING
The indicator and alarm unit must be installed in a place where someone is always present and is easy to
read so that taking countermeasures and notifying others in case of an alarm is possible.
Do not place the indicator and alarm unit in a place with vibration, electric noise, or corrosive gas. Avoid
places with a high temperature or humidity as well.
CAUTION
As to the gas detector to be connected, refer to its instruction manual.
MEMO
Size of mounting holes is different if the equipment has a backup power source.
If the equipment has no backup power source, a cable can be connected from the back and bottom of the
equipment. If the equipment has a backup power source, a cable can be connected only from the bottom.
Leave a 30 cm space under the equipment’s body for maintenance work. If the equipment has a backup
power source, also leave a 30 cm space on the right side of the equipment for changing batteries.
MEMO
Fig. 6 Dimensions for Hanging the Equipment on the Wall
With a backup power source
Without a backup power source
(Cable inlet)
2-
φ
30
3-
φ
7
3-
φ
7
2-
φ
7
113
113
60
70
8.5
172
204
220
234