7
Please place it vertically for use, otherwise the test result may be affected
(9) Water Leak
When the leak sensor is immersed in water,it will immediately issue a report, leaking status:1.
When the leak sensor is out of the immersion state, a report is issued immediately, with no water leakage
status: 0
➢
If the DO out function is available, a signal will be output to the DO out after the water leakage is triggered. (it
is off by default)
(10) Dry Contact IN
When the dry contact is disconnected (open circuit): Report 0
When dry contact is connected (short circuit): Report 1
➢
If the DO out function is available, a signal will be output to the DO out after the dry
contact in is triggered.
(11) Seat Occupancy
When the seat occupancy sensor detects that the occupancy status has changed,
The seat is occupied: report 1
The seat is not occupied: report 0
➢
Report follows IR disable time and IR detection time rules.
(12) DO OUT
When PIR
、
emergency button alarm
、
reed switch
、
leakage
、
tilt
、
internal vibration
、
external vibration
、
glass break=1 (Alarm),
then DO OUT = 1 ( Hight level , enable)
➢
DO OUT default is 0. (Low level, disable)
➢
It can be turned on by command, and the output time can be configured by command.
➢
Only one DO OUT function can be enabled at most.
(13) Glass Break
No broken glass detected: report 0
Broken glass detected: report 1
➢
If the DO out function is available, a signal will be output to the DO out after the glass is
broken. (it is off by default)
(14) Buzzer (optional)