9
While IRDetectionTime is 60 secs and IRDisableTime is 30 secs, living creature is detected during 25
th
sec.
PIR/seat occupancy will restart IR detect procedure(IRDetectionTime).
No living creature is detected during next IRDetectionTime and PIR/seat occupancy therefore report un-occupied.
5.2.2 Restore Rereport
➢
Applicable sensor:
Internal vibration sensor, external vibration sensor
RestoRereportSet = 0x00, only sends vibration data
RestoRereportSet = 0x01, sends vibration data and vibration stop data,
When the light sensor is disable, the vibration stop data is sent 10 seconds after the vibration stops.
When the light sensor is enable, the stop vibration stop data will be sent 30 seconds after the vibration
stops
5.2.3 LastMessageResendtime
➢
Applicable sensor:
Reed switch, tilt sensor
When the device is triggered quickly, additional data can be sent
Resendtime=0,
When the
reed switch
is closed immediately after magnetic opening, it will only receive
reed
switch status =1
Resendtime=3,
Close the reed switch as soon as it is opened, and you will receive reed switch status =1,
It will be received after 3 seconds reed switch status =0
Resendtime = 0x00 or 0xFF, No additional data will be sent
Resendtime = 0x03 to 0xFE, The device will send data after triggering, and then supplement the last status
data after 3-254s
IRDetectionTime = 60 s
IRDisableTime = 30 s
IRDisableTime = 30 s
Turn on for 9 s
(30%)
Turn off for 21 s.
(70%)
25 s
Turn off for 21 s.
(70%)
Turn on for 9 s
(30%)
Turn on for 9 s
(30%)