24
Example#2
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. Battery Voltage Change=
0.1V.
Example#3
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. Battery Voltage Change=
0.1V.
Note:
1.
The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it
does not collect data.
2.The data collected is compared with the last data reported. If the data change value is greater than the
ReportableChange value, the device reports according to MinTime interval. If the data variation is not greater
than the last data reported, the device reports according to MaxTime interval.
3.We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device
wakes up frequently and the battery will be drained soon.
4.Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime
interval, another cycle of MinTime / MaxTime calculation is started.
0H
15
th
30
th
45
th
1H
Wake up and collects data
REPORTS 2.8V
Wakes up and collects data 2.8V
Does not report
Max Time
Min Time
Min Time
(Sleeping)
(Sleeping)
Wakes up and collects data
REPORTS 2.8V
(Sleeping)
Min Time
(Sleeping)
Min Time
0H
15
th
30
th
45
th
1H
Min Time
Min Time
(Sleeping)
(Sleeping)
(Sleeping)
Min Time
(Sleeping)
Min Time
Wakes up and collects data
REPORTS 2.8V
1H10
th
M
1H25
th
M 1H40
th
M 1H55
th
M 2H10
th
M
Max Time
Min Time
Min Time
(Sleeping)
(Sleeping)
(Sleeping)
Min Time
(Sleeping)
Min Time
Wakes up and collects data 2.7V
Does not report
Users push the button
REPORTS 2.7V.
Wakes up and collects data
REPORTS 2.7V
Wakes up and collects data 2.7V
Does not report