background image

 

 

1. Introduction   

The R311FA is a Wireless Activity Detection Sensor for Netvox ClassA type devices based on the 

LoRaWAN open protocol and is compatible with the LoRaWAN protocol. 

When the device detects movement or vibration, it immediately triggers an alarm. 

 

LoRa Wireless Technology: 

LoRa is a wireless communication technology dedicated to long distance and low power consumption. 

Compared with other communication methods, LoRa spread spectrum modulation method greatly 

increases to expand the communication distance. Widely used in long-distance, low-data wireless 

communications. For example, automatic meter reading, building automation equipment, wireless 

security systems, industrial monitoring. Main features include small size, low power consumption, 

transmission distance, anti-interference ability and so on. 

 

LoRaWAN: 

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability 

between devices and gateways from different manufacturers.   

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание R311FA

Страница 1: ...o Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in who...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 4 4 Set up Instruction 5 5 Data Report 7 6 Installation 12 7 Relative Devices 13 8 Important Maintenance Instruction 13...

Страница 3: ...ed with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For exam...

Страница 4: ...3 2 Appearance Indicator Battery cover Function Key Function Key...

Страница 5: ...s data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Improved power management for longer battery life Batte...

Страница 6: ...ge components 3 Press any function key and insert batteries at the same time it will enter engineer testing mode Network Joining Never joined the network Turn on the device to search the network to jo...

Страница 7: ...ns off Sleeping Mode The device is on and in the network Sleeping period Min Interval When the reportchange exceeds setting value or the state changes send a data report according to Min Interval The...

Страница 8: ...8 m s2 The scale factor of the threshold is 62 5 mg R311FA vibration alarm The device detects a sudden movement or vibration change of the quiescent state and it will immediately send a report After t...

Страница 9: ...terval Unit second Max Interval Unit second Reportable Change Current Change Reportable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Repor...

Страница 10: ...Device Type NetvoxPayLoadData SetR311F TypeReq R311F A 0x03 0x4F R311FType 1Bytes 0x01_R311FA 0x02_R 311FB 0x03_R311FC Reserved 8Bytes Fixed 0x00 SetR311F TypeRsp 0x83 Status 0x00_success Reserved 8B...

Страница 11: ...based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping sleeping sleeping 0H 15th M 30th M 45th M 1H 2H Wakes up and collects data...

Страница 12: ...e reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be draine...

Страница 13: ...vement or vibration and it will immediately sends a report After the vibration alarm the device waits for a certain period of time DeactiveTime default 5 seconds can be modified to enter the quiescent...

Страница 14: ...hen the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit b...

Отзывы: