NV-600WI Managed Industrial Grade Wireless VDSL2 Router USER’S MANUAL Ver. A2
27
Power Input Status
The following Table shows the examples of the power input status. (
Table 3-4
)
Table 3-4
Example 1
Example 2
Example 3
Power
Item
Default
Polarity
Power
Input1
Output
State1
Power
Input2
Output
State2
Power
Input1
Output
State1
Power
Input2
Output
State2
Power
Input1
Output
State1
Power
Input2
Output
State2
–
12V
–
12V
–
12V
+
12V
+
48V
–
Power 1
+
12V
+
OFF
12V
+
ON
12V
–
Protection
12V
–
Protection
48V
+
ON
No
Power
OFF
–
24V
–
24V
–
48V
–
48V
–
Power 2
+
24V
+
ON
No
Power
OFF
24V
+
ON
No
Power
OFF
48V
+
ON
48V
+
ON
Example 4
Example 5
Example 6
Power
Item
Default
Polarity
Power
Input1
Output
State1
Power
Input2
Output
State2
Power
Input1
Output
State1
Power
Input2
Output
State2
Power
Input1
Output
State1
Power
Input2
Output
State2
–
12V
–
12V
–
12V
–
12V
–
48V
–
Power 1
+
12V
+
Malfunction
12V
+
Malfunction
12V
+
ON
12V
+
Malfunction
48V
+
ON
No
Power
OFF
–
60V
–
60V
–
48V
+
48V
+
Power 2
+
60V
+
Malfunction
No
Power
Malfunction
No
Power
OFF
60V
+
Malfunction
48V
–
Protection
48V
–
Protection
Notes:
1. State 1 always happens before State 2.
2. Protection means enable Reverse Polarity Protection function.
3. Please note that if use different DC voltage, higher voltage will feeding to NV-600LI or NV-600WI.
4. Please note that the warranty is void if DC 48V power input is exceeded.