RS-485 Port Specification (Option Sa)
The RS-485 port has the following specification (bold characters show the default configura-
tion):
Feature
Specification
Protocol
3-wire RS-485 (GND, A, B)
Baud rate
600,
1 200,
2 400,
4 800,
9 600,
19 200,
38 400, 57 600,
115 200
, 230 400, 460 800
Data bits
7 bit,
8 bit
Parity
none
, odd, even
Stop bits
1
, 2
Software flow control
none
, XON/XOFF
Hardware flow control
none
Galvanic isolation to enclosure
1500 V
DC
Internal bus termination
none
Max. cable length
10 m
Cable shield
mandatory
Cable type
Twisted Pair
Max.
number of transceivers on
bus
256
Max. number of nodes
256
Table 3.30.: RS-485 Port Specification
EP Pins
Signal
1 / 5
GND
2 / 6
TxD
−
/RxD
−
(A)
3 / 7
TxD
+
/RxD
+
(B)
4 / 8
−
Table 3.31.: Pin Assignments of RS-485 Port Signals (EP1 / EP2)