MegaNet
TM
USER MANUAL
21
Special model with anti-drain valve
For use in slopped fields in order to prevent drainage of the distribution pipe and
possible over-saturation of the soil, unwanted puddles or landslide.
Features and benefits
•
Automatic end-of-irrigation shut-off valve.
•
Prevents water backflow or drainage of the system into low areas.
•
Eliminates the need for system water refill at the beginning of the next irrigation cycle.
•
Shut-off pressure: 0.6 bar
Installation
The installation process of this model is similar to that of the regular model
(see
pages 10-19
).
Screwing and tightening of the sprinkler can be done by hand. The use of a 20 mm
spanner is not necessary.
Adding a PRV (pressure regulating valve)
Install a PRV at the sprinkler inlet when a 100% flow rate and
distribution uniformity is required.
The presented model is suitable for an exit pressure of 2.5 bar.
For other exit pressure values, contact your local Netafim™
representative.
Installation
The installation process of the sprinkler and PRV is similar to that
of installation on solid set riser pipes (see
page 12
).
Screwing and tightening of the PRV should be done by hand.
ATTENTION
Make sure the PRV is connected to the sprinkler
with the arrow pointing towards the sprinkler (up).
NOTE
The PRV bottom thread is ¾" female. To connect the PRV to
a riser with a thread that is not ¾" male, use an apropriate
adapter/reducer from the vast selection offered by Netafim™
(see
page 26
and at
XXX
).
APPENDIX 1: SPECIAL APPLICATIONS
Arrow
¾" male
thread