MegaNet
TM
USER MANUAL
13
To assure proper operation of the sprinkler, a simple inspection and maintenance procedure should be
carried out regularly.
Rinsing the filter
Frequency:
Before the beginning of each growing season
or in case one the following symptoms occurs:
•
The sprinkler doesn't emit water.
•
The flow of water emitted is low.
Action:
1.
Open the sprinkler by unscrewing the upper body of the
sprinkler from its base.
2.
Detach the filter by pulling it down.
3.
Clean the filter from the inside with a water jet or pressurized air.
4.
Put the filter back in place.
CAUTION
Never operate the sprinkler without the filter.
Failure to comply with this instruction will clog the sprinkler,
and may damage it and void the warranty.
5.
Reassemble the sprinkler.
MAINTENANCE
1
2
3