background image

10 

 

MegaNet

TM

  

USER MANUAL

TECHNICAL DATA

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

192

203

216

225

230

1%

234

252

272

288

300

Flat terrain 0

282

308

336

360

390

Downhill

-1%

318

357

392

423

460

-2% 348

392

432

477

520

Nominal 

flow rate: 

200 l/h*

Max. lateral length - 10% flow variation (cont'd)

Inlet pressure: 3.0 bar

Lateral: PE 50 mm  

ID: 45.4 mm

Lateral: FlexNet

 2"  

ID: 50.4 mm

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

174

189

200

207

220

1%

210

224

240

261

270

Flat terrain 0

246

273

296

315

340

Downhill

-1%

276

308

336

369

400

-2% 300

336

376

405

440

Nominal 

flow rate: 

250 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

150

161

176

180

190

1%

174

189

208

216

230

Flat terrain 0

198

217

240

261

280

Downhill

-1%

222

245

272

297

320

-2% 234

266

296

324

350

Nominal 

flow rate: 

350 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

138

147

160

171

180

1%

156

168

184

189

210

Flat terrain 0

174

189

208

225

240

Downhill

-1% 186

210

232

252

270

-2% 198

224

248

270

290

Nominal 

flow rate: 

450 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

126

133

144

153

160

1%

138

154

168

180

190

Flat terrain 0

156

168

184

198

210

Downhill

-1% 168

182

200

216

240

-2%

174

196

216

234

260

Nominal 

flow rate: 

550 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

114

126

136

144

150

1%

126

133

144

162

170

Flat terrain 0

138

147

160

180

190

Downhill

-1%

144

161

176

189

210

-2% 156

168

192

207

220

Nominal 

flow rate: 

650 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

108

112

120

135

140

1%

114

126

136

144

160

Flat terrain 0

126

140

152

162

170

Downhill

-1%

132

147

160

171

190

-2% 138

154

168

189

200

Nominal 

flow rate: 

750 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

210

224

232

243

250

1%

264

287

304

324

340

Flat terrain 0

336

371

400

432

460

Downhill

-1%

390

434

480

522

560

-2% 432

483

536

585

640

Nominal 

flow rate: 

200 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

198

210

216

225

230

1%

240

259

280

297

310

Flat terrain 0

294

322

352

378

410

Downhill

-1%

336

378

416

450

490

-2%

372

413

464

504

550

Nominal 

flow rate: 

250 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

174

182

192

207

210

1%

204

224

240

252

270

Flat terrain 0

240

259

288

306

330

Downhill

-1%

264

294

328

360

380

-2% 288

322

360

396

430

Nominal 

flow rate: 

350 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

156

168

176

189

200

1%

180

196

208

225

240

Flat terrain 0

204

224

248

270

280

Downhill

-1%

228

252

280

297

320

-2% 246

273

304

333

360

Nominal 

flow rate: 

450 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

144

154

168

171

180

1%

162

175

192

207

220

Flat terrain 0

180

203

216

234

250

Downhill

-1% 198

224

248

270

290

-2%

216

238

264

288

310

Nominal 

flow rate: 

550 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

132

140

152

162

170

1%

144

161

168

180

190

Flat terrain 0

162

175

192

207

220

Downhill

-1%

174

196

216

234

250

-2% 186

210

232

252

270

Nominal 

flow rate: 

650 l/h*

S

lo

pe

Distance between sprinklers (m)

6

7

8

9

10

Max. lateral length (m)

Uphill

2%

120

133

144

153

160

1%

132

147

160

171

180

Flat terrain 0

150

161

176

189

210

Downhill

-1%

156

175

192

207

230

-2% 168

189

208

225

240

Nominal 

flow rate: 

750 l/h*

*Nominal flow rate at 2.3 bar working pressure.

Содержание MegaNet 15D

Страница 1: ...V 002 01 JULY 2017 MEGANET TM USER MANUAL ROTATING IMPACT SPRINKLER...

Страница 2: ...ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM USE OF NETAFIM S PRODUCTS OR USE OF THIS MANUAL NETAFIM RESERVES THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS TO ITS PRODUCTS AND OR THE ASSOCIATED DOCUM...

Страница 3: ...Head loss in riser tube Installation Introduction Various installation configurations Maintenance Rinsing the filter Checking the turbine and the cover Cleaning the nozzle Parts and complementary prod...

Страница 4: ...The following text contains instructions aimed at preventing foot injury TIP The following text provides clarification tips or useful information Use of symbols The symbols used in this manual refer t...

Страница 5: ...ound the MegaNet does not groove the soil along the whole irrigation event including startup and shut off which prevents the seeds from being exposed out of the soil Reduced maintenance cost The MegaN...

Страница 6: ...t connector to be glued to PVC 1 2 ASTM inlet connector to be glued to PVC Code colored locking pins and caps for easy identification 2 balanced water jets Individual filter in each sprinkler MegaNet...

Страница 7: ...st 0 5 mm h MegaNet 24D Water trajectory angle 24 degrees Pin color code Black Nozzle size mm Color code Working pressure bar Flow rate l h Wetted diameter m Spacing rectangular m x m 7 x 8 8 x 8 8 x...

Страница 8: ...ple 2 5 258 12 4 4 4 0 3 0 283 4 8 4 4 2 44 Green 2 5 362 14 5 9 5 6 4 5 4 4 3 6 3 0 396 6 5 6 2 5 0 4 9 4 0 2 79 Blue 2 5 461 17 8 1 7 2 5 8 5 7 4 6 4 2 3 9 3 0 505 8 7 7 9 6 3 6 2 5 0 4 6 4 2 3 08 B...

Страница 9: ...64 72 70 Flat terrain 0 54 63 64 72 80 Downhill 1 54 63 72 72 80 2 60 63 72 81 80 Nominal flow rate 750 l h Slope Distance between sprinklers m 6 7 8 9 10 Max lateral length m Uphill 2 150 161 176 18...

Страница 10: ...2 108 112 120 135 140 1 114 126 136 144 160 Flat terrain 0 126 140 152 162 170 Downhill 1 132 147 160 171 190 2 138 154 168 189 200 Nominal flow rate 750 l h Slope Distance between sprinklers m 6 7 8...

Страница 11: ...jectory angle 24 degrees Pin color code Black Height m Distance from head m Height m Distance from head m 200 1 85 Yellow 1 00 4 75 1 42 4 88 250 2 06 Purple 350 2 44 Green 450 2 79 Blue 1 11 5 13 1 6...

Страница 12: ...e and mining irrigation applications IMP SPR stand a diameter stand satisfactorily used by farmers all over the globe for many years It became a classic in open field and orchard irrigation due to its...

Страница 13: ...sn t emit water The flow of water emitted is low Action 1 Open the sprinkler by unscrewing the upper body of the sprinkler from its base 2 Detach the filter by pulling it down 3 Clean the filter from...

Страница 14: ...le it also serves to hold the cover and the turbine in place 4 Push the sprinkler s top mechanism up and hold it 5 Remove the colored cover by pulling it up 6 Remove the turbine by pulling it up 7 Vis...

Страница 15: ...ughout the dismantling and reassembling process and do not interfere with it NOTE 2 service keys are supplied with each box of MegaNet sprinklers Additional service keys can be ordered separately Cat...

Страница 16: ...e sprinkler perform the steps above in reverse order When putting the diverter back in place turn the key clockwise until the diverter snaps in place A click should be heard CAUTION When reassembling...

Страница 17: ...s p pallet Total units p pallet Pallet weight Kg Head only 200 18 x 34 x 79 11 0 20 4000 232 MegaNet cover Flow rate l h 200 250 350 450 550 650 750 Color code Yellow Purple Green Blue Brown Orange Re...

Страница 18: ...uct description Road protector Catalog number 63620 007000 Product description Service key Catalog number 63620 004500 Complementary products Product description In line pressure regulator female fema...

Страница 19: ...08 Brown 63600 010200 63600 010600 650 3 37 Orange 750 3 68 Red Models for specific uses head only Special model with anti drain valve Product description threaded inlet connector AD Flow rate l h No...

Страница 20: ...outer surface of the sprinkler housing with the primer 6 Wait 60 seconds for the primer to dry befor applying the cement and then neatly apply the cement to the outer surface of the sprinkler housing...

Страница 21: ...spanner is not necessary Adding a PRV pressure regulating valve Install a PRV at the sprinkler inlet when a 100 flow rate and distribution uniformity is required The presented model is suitable for an...

Страница 22: ...e the road protector on top of the sprinkler with its back side facing the road you want to protect from water 2 Push the road protector down onto the sprinkler head Clicks should be heard 3 Slightly...

Страница 23: ...a MegaNet sprinkler or part resulting from misuse negligence alteration force majeure lightning improper installation or improper maintenance including any maltreatment of the MegaNet sprinkler or an...

Страница 24: ...GROW MORE WITH LESS WWW NETAFIM COM...

Отзывы: