16
MegaNet
TM
USER MANUAL
MAINTENANCE
Diverter
5.
Release the diverter using the other end of the
second service key.
Clean
6.
Clean the nozzle from the top with a water jet or
pressurized air.
7.
To reassemble the sprinkler perform the
steps above in reverse order.
When putting the diverter back in place, turn the
key clockwise until the diverter snaps in place.
A click should be heard.
CAUTION
When reassembling the sprinkler, do not
forget to put the filter in place to avoid
clogging the nozzle in the future.
Hold the first service key in place and turn the
second service key counterclockwise to release the
diverter.