In the event that the sprinkler has been operated without the filter in place, it is possible to clean the nozzle.
Follow the instructions below:
NOTE
The drawings below present the sprinkler's upper body without the pin, the colored cover and the
turbine, to show the actions described. In practice, these 3 parts are connected to the top of the
diverter throughout the dismantling and reassembling process, and do not interfere with it.
NOTE
2 service keys are supplied with each box of MegaNet™ sprinklers. Additional service keys can be
ordered separately (Cat. No. 63620-004500).
1.
Open the sprinkler by unscrewing the upper body of the sprinkler from its base (see
page 21
, step 1).
2.
Push the sprinkler's top mechanism up and hold it (see
page 21
, step 4).
MAINTENANCE
Groove
Tab
Tab
Slot
3.
Insert the slotted end of a service key
underneath the diverter holder.
4.
Push the far end of the service key down to the horizontal
position with the groove underneath the key resting on the rim
of the sprinkler's upper body. In this position, the service key
should hold in place.
ATTENTION
There are 2 opposing tabs on the underside
of the diverter holder. Make sure that the
slot of the service key holds one of the tabs.