5.4 Troubleshoot
Sensors and Controllers / Transmitters are not designed to be repaired in the field. If a problem should develop,
first check for faulty wiring, confirm proper voltage to detector, and attempt a calibration. If the problem
persists, please contact Net safety’s service department first by phone to try and resolve the issue. If the issue
cannot be resolved, please follow the procedure below on how to return equipment.
5.5 Spare Parts / Accessories
Table 6: Available Spare Parts
Description
Net Safety Part Number
Calibration Cup / Splash Guard
CCS-1
Separation Kit
JB-MPD-A (aluminum) or JB-MPD-S (316 stainless steel)
Dust Filter Assembly
DSC-1
Replacement Oxygen (O2) Sensor
ST340-25