N e p t u n e
™
1 . 2 5 H P P o o l P u m p M o t o r
I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l
21
Contact US Motors/Nidec Motor Corporation for the proper communication protocol. If an external
controller is used, make sure the line is an isolated, non-grounded connection.
Press the
MENU/ENTER
button once to enter
Navigation Mode
. Press
Scroll Up
or
Scroll Down
to select the
Standard Settings
menu tree. Press
MENU/ENTER
to enter the menu tree. Press
Scroll Down
until you reach the Remote Control screen. Press
MENU/ENTER
again to enter
Input Mode
. Press
Scroll Up
or
Scroll Down
to toggle the setting. Press
MENU/ENTER
to save
the changes. Press
START/PAUSE
to exit the menu option and return to the menu tree in
Navigation Mode
. Press
START/PAUSE
again to return to normal operations.
If
Remote Mode
is enabled and you want to return control of the pump to the UI, follow these steps.
1. Press the
Speed 2
and
Speed 3
buttons simultaneously and hold them down for five seconds.
Note
: If a button press is not detected in ten (10) seconds, the UI reverts to
Remote Mode
.
2. Press
MENU/ENTER
to save the changes and return to
Navigation Mode
.
After confirming the change, the pump stops, if it is running, and moves to
Standby Mode
in which
you can program the motor from the UI. The pump no longer responds to commands from the
external control system. Press
START/PAUSE
to enable the run schedule.
Node ID
Node ID
is used to determine whether the integrated UI or an external controller (
Remote Mode
)
has ultimate command over the operation of the motor.
Note
: This option is not available unless the
Remote Control setting above is Enabled.
The
Node ID
can be set to any number between 1 and 247. The default number is 240.
Also, a DIP
Switch can be used to set the
Node ID
, if
Remote Mode
is enabled.
See
page 24
for additional
information. A DIP Switch ID other than zero (0) takes priority over the
Node ID
in the UI menu.
Conversely, with a DIP Switch setting of zero (0), the
Node ID
is read from the integrated UI.
Press the
MENU/ENTER
button once to enter
Navigation Mode
. Press
Scroll Up
or
Scroll Down
to select the
Standard Settings
menu tree. Press
MENU/ENTER
to enter the menu tree. Press
Scroll Down
until you reach the Node ID screen. Press
MENU/ENTER
again to enter
Input Mode
.
Press
Scroll Up
to increase the digit or
Scroll Down
to decrease the digit. Press
MENU/ENTER
to
save the changes. Press
START/PAUSE
to exit the menu option and return to the menu tree in
Navigation Mode
. Press
START/PAUSE
again to return to normal operations.
Reset To Factory
This setting allows you to reset all parameters in the
Standard Settings
and
Custom Settings
menus back to the factory default settings. Refer to
page 31
for a list of the default parameters.
Press the
MENU/ENTER
button once to enter
Navigation Mode
. Press
Scroll Up
or
Scroll Down
to select the
Standard Settings
menu tree. Press
Scroll Down
until you reach the Reset To Factory
screen. Press
MENU/ENTER
again to enter
Input Mode
. The Reset Parameters screen appears.
“Are you sure?!”
flashes on the second line. Press
MENU/ENTER
to confirm the choice and save the
changes. Press
START/PAUSE
to exit the menu option and return to the menu tree in
Navigation
Mode
. Press
START/PAUSE
again to return to normal operations.