24
Wiring a Remote Connection
You can attach any RS485-compatible cable to the RS485 connector.
The drive interface board is located in the Low Voltage Compartment and is powered by an isolated, low
voltage, 5 Vdc electrical power supply. Follow these steps to wire a remote connection:
1. Remove the four (4)
slotted head hex washer screws
securing the Wiring Compartment Cover. Set
the cover aside.
2. Remove the conduit plug and feed the RS485 cable (not supplied) through the
1/2”
NPT conduit
hole on the end of the compartment.
3. Attach the cable to the RS485 Connector to the interface board.
The 3-position DIP Switch on the interface board can be used to identify a specific MODBUS ID. A DIP
Switch ID other than zero (0) takes priority over the
Node ID
menu in the integrated UI.
Note
:
Configuring MODBUS communications assumes that you are familiar with the MODBUS RTU protocol.
The MODBUS ID settings on the DIP Switch are as follows:
DIP 1
DIP 2
DIP 3
Function
DIP Switch
OFF
OFF
OFF
MODBUS ID (default)
(default)
OFF
OFF
ON
MODBUS ID 1
OFF
ON
OFF
MODBUS ID 2
OFF
ON
ON
MODBUS ID 3
ON
OFF
OFF
MODBUS ID 4
ON
OFF
ON
MODBUS ID 5
ON
ON
OFF
MODBUS ID 6
ON
ON
ON
MODBUS ID 7
To activate remote control of the pool motor, ensure that you have also enabled the Remote Control
setting via the UI. See the Remote Control setting on
page 20
for more information.
RS485
Connector
DIP
Switch