2.15 Clock: +CCLK
Description
To set and query the real-time clock
Format
AT+CCLK=<time><CR>
AT+CCLK?<CR>
Parameter
<Time>: String, in the format "yy/mm/dd, hh:mm:ss+TZ", indicating year, month,
day, hour, minute, second
TZ: 2 digits indicate the difference between local time and GMT. This information
is optional and is displayed only if the network supports it.
Return value
See the Example.
Example
AT+CCLK="11/10/14,09:30:16"
OK
Set the real-time clock of the module.
AT+CCLK="11/10/14,09:30:"
ERROR
Command format is incorrect.
AT+CCLK?
+CCLK: "11/10/14,09:32:04"
OK
Query the setting of the real-time clock.
Remark
The settings will not be saved after the module is powered off.
2.16 Enabling PIN and Querying MT and Network Device:
+CLCK
Description
To lock, unlock or interrogate an MT or a network facility
Format
AT+CLCK=<fac>,<mode>[,<passwd>[,<class>]]<CR>
AT+CLCK=?<CR>
Parameter
<<fac>: A pair of quotation marks is must for the value.
"OI": Outgoing international calls
"SC": SIM card
"AO": All outgoing calls
"OX": All outgoing international calls except to the home country
"FD": SIM fixed dialing memory feature
<mode>:
Содержание N11 V2
Страница 1: ...N11 V2 AT Command Manual Issue 1 0 Date 2018 10 19 Neoway Product Document...
Страница 15: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 7 OK Remarks The default status setting is 7...
Страница 129: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 121 not support proactive time issuing...
Страница 134: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 126...