N11 V2
AT Command Manual
Copyright © Neoway Technology Co., Ltd
14
0: Set the response format to output with only some header, footer, and digit text.
1: Set the response format to output with all headers, footers, and detailed
response text (default).
Return Value
See the Example.
Example
ATV1
OK
AT+CSQ
+CSQ: 31, 99
OK
Set the response format to output
with all headers, footers, and
detailed response text.
ATV00
AT+CSQ
+CSQ: 31, 990
Set the response format to output
with only some header, footer, and
digit text. The module returns 0 after
the format is set successfully.
Remarks
ATV is equal to ATV1.
After
ATV0
isexecuted, the return value for a command in correct format is 0
(default setting is OK) which will follow the command; 4 for command in
incorrect format (default setting is ERROR).
The setting by this command will not be saved after the module is powered
off.
2.7 Resetting to the Default Setting: ATZ
Description
To reset the module to the default settings
Format
ATZ[<value>]<CR>
Parameter
<value>: 0, 1
The command is used to reset the module to the default settings both with valid
parameter values and without this parameter.
Return Value
See the Example.
Example
ATZ0
OK
Reset the module to the default
setting.
Remarks
If the module is set to the code result suppression mode (ATQ1), reset it to the
default settings by executing this command.
Содержание N11 V2
Страница 1: ...N11 V2 AT Command Manual Issue 1 0 Date 2018 10 19 Neoway Product Document...
Страница 15: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 7 OK Remarks The default status setting is 7...
Страница 129: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 121 not support proactive time issuing...
Страница 134: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 126...