N11 V2
AT Command Manual
Copyright © Neoway Technology Co., Ltd
28
Return Value
<CR><LF>+POSI: MODE,MCC,MNC,LAC,CI,BSIC, RxLev,ENDED[…]
<LF>OK<CR><LF>
MODE: 1, indicating that all base station information will be read
MCC: Country code
MNC: Mobile network code, hexadecimal
LAC: Area code, hexadecimal
CI: Cell ID, hexadecimal
BSIC: Base station ID, hexadecimal
RxLev: Signal strength of the base station, expressed by 1 to 64
ENDED: End symbol. 0 indicates there is more base station information; 1 indicates
that this is the last line of the base station information.
Example
AT+POSI=1
+POSI:1,460,00,27A8,EA7,1D,7,1
OK
Obtain
the
information of one
base station.
AT+POSI=1
+POSI:
1,460,01,2543,A85D,3E,45,0,460,01,2543,AB13,1E,41,0,4
60,01,2543,A85E,10,36,0,460,01,2543,AA51,0A,34,0,460,
01,2543,B046,11,32,0,460,01,2543,A9A8,3F,31,0,460,01,
2543,A805,33,27,1
OK
Obtain
the
information
of
multiple
base
stations.
Remarks
If no cell is found, the module returns OK.
If there are multiple pieces of base station information, the data circulates
between MCC and ENDED.