N11 V2
AT Command Manual
Copyright © Neoway Technology Co., Ltd
118
name with or without quotation marks)
Return Value
See the Example
Example
AT+PING=www.baidu.com
OK
Reply from 183.232.231.172: bytes= 36 time =
780(ms), TTL = 255
Reply from 183.232.231.172: bytes= 36 time =
299(ms), TTL = 255
Reply from 183.232.231.172: bytes= 36 time =
719(ms), TTL = 255
Reply from 183.232.231.172: bytes= 36 time =
755(ms), TTL = 255
Reply from 183.232.231.172: bytes= 36 time =
299(ms), TTL = 255
Ping statistics for 183.232.231.172
Packets: Sent = 5, Received = 5, Lose = 0 <0%>,
max_delay = 780 ms, min_delay = 299 ms, average
delay = 570 ms
PINGwww.baidu.com
Send 4 request data
packets
(12
bytes)
continuously.
Receive
4
response
packets (32 bytes).
AT+PING=192.168.2.61
OK
Request timed out.
Request timed out.
Request timed out.
Request timed out.
Ping statistics for 192.168.2.61:
Packets: Sent = 4, Received = 0, Lose = 4 <100% loss>
PING 192.168.2.61
Send 4 request data
packets
(12
bytes)
continuously.
Receive
0
response
packets
because
of
timeout.
AT+PING=www.baidu.com
+PING: No PPP Link
No PPP connection is set
up.
Remarks
A PPP connection must be set up before using this command.
Содержание N11 V2
Страница 1: ...N11 V2 AT Command Manual Issue 1 0 Date 2018 10 19 Neoway Product Document...
Страница 15: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 7 OK Remarks The default status setting is 7...
Страница 129: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 121 not support proactive time issuing...
Страница 134: ...N11 V2 AT Command Manual Copyright Neoway Technology Co Ltd 126...