3.7.3 Operation Modes of Ignition Power Control
If the option of ignition power control modules is available, you can use the rotary switch on
SBC to configure the operation mode. Nuvo-3100VTC offers 8 operation modes (Rev. A1)
or 16 operation mode (Rev. A2 or later) with different power-on/power-off delay
configurations.
Note
For Nuvo-3120 Rev. A1 (S/N from E2500001 to E2500100), please always set the rotary switch to 8
otherwise the system may be failed to operate.
For Nuvo-3100VTC Rev. A1
Mode 0
Mode 0 is the ATX mode without power-on and power-off delay. User can only use the
power button on the front panel to turn on or turn off the Nuvo-3100VTC system.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
0
N/A
N/A
N/A
Mode 1
If Mode 1 is specified, the system automatically turns on the system when DC power
is applied. A retry mechanism is designed to repeat the power-on cycle if the system is
failed to boot up.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
1
N/A
N/A
N/A
Mode 2 / Mode 3 / Mode 4 / Mode 5
Mode 2 ~ Mode 5 are ignition power control modes with various power-on delay and
power-off delay. Each mode supports a hard-off timeout of 10 minutes.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
2
10 seconds
10 seconds
10 minutes
3
30 seconds
1 minute
10 minutes