Nuvo-3100 Series User’s Manual
Copyright © 2014 Neousys Technology Inc. All Right Reserved.
Page 21 of 99
2.3.2
IGN On/Off Delay Configuration Switch (Nuvo-3100VTC Only)
Nuvo-3100VTC features intelligent ignition power control with user-configurable power
on/off delay. The IGN on/off delay configuration switch on the back panel allows users to
adjust duration of power-on delay and power-off delay per application’s requirement. A total
of 8 modes are available for Rev. A1 (S/N from E2500000 to E2500100) and a total of 16
modes are available for Rev. A2. Please refer to section 3.7 for more information regarding
ignition power control.
IGN On/Off Delay Configuration for Nuvo-3100VTC Rev. A1
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
0
ATX mode
1
AT mode (power on after power supplied)
2
10 seconds
10 seconds
10 minutes
3
30 seconds
1 minute
10 minutes
4
30 seconds
5 minutes
10 minutes
5
30 seconds
30 minutes
10 minutes
6
30 seconds
2 hours
10 minutes
7
30 seconds
5 hours
10 minutes
IGN On/Off Delay Configuration for Nuvo-3100VTC Rev. A2
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
0
ATX mode
1
AT mode (power on after power supplied)
2
Remote On/Off control mode
(available for both Nuvo-3100VTC & Nuvo-3120)
3
10 seconds
10 seconds
10 minutes
4
10 seconds
1 minute
10 minutes