. Safety instructions
�
.
�
Safety warnings
�
Read the instructions carefully before installing, commissioning or maintaining the equipment. Compliance with
the described procedures for installation and operation of the equipment is important for years of trouble-free
operation. Failures and malfunctions that result from non-compliance with safety instructions, installation
procedures and operating rules will not be taken into account, including damage or destruction of other related
equipment. Installation of the device may only be carried out by persons with appropriate quali
�
cations in the
�
eld
of heating, refrigeration and electrical engineering.
Furthermore, all applicable safety regulations related to the installation and operation of the NeoRé heat pump
must be observed.
The device can only be operated by a person familiar with this manual and older than
��
years. Persons with limited
physical, sensory and mental abilities or lack of experience and/or knowledge may only operate the equipment if
they are under the supervision of a person who is responsible for their safety or if they have been trained by that
person about safe use of the equipment and understood the risks involved. Children are not allowed to play with
the equipment or perform its cleaning and maintenance.
�
R
��
refrigerant is an A
�
L class
�
ammable gas
The minimum
�
oor area condition must be met to install the indoor unit. More detailed in
the
Installation manual, chapter Refrigerant pipes, table Minimal
�
oor area for A
�
L gasses
.
�
.
�
Safety precautions
�
The heat pump is an electrical device operating at
���
V! The appliance may only be installed and serviced by an
authorized electrician. Do not extinguish with water or foam in case of
�
re. Use only powder or snow extinguisher!
In case of refrigerant leakage, switch off all circuit breakers located on the indoor unit and contact the service
organization indicated on the label on the indoor unit. R
��
refrigerant is slightly
�
ammable, non-toxic. Under no
circumstances you should try to stop the refrigerant leakage yourself. It develops very low temperatures (up to
50
°
C). In the event of a leak in the interior of the building, ventilate the room. In case of inhalation of refrigerant
vapours or
�
re fumes, transport the af
�
icted person to a ventilated place and call for medical assistance: phone
number
���
. In case of contact with liquid refrigerant, dry the area immediately and heat with a blanket. In case
of eye contact with liquid refrigerant, rinse with plenty of lukewarm water and call for medical assistance: phone
number
���
.
�
Содержание 11 TG TX
Страница 6: ...Table of technical parameters Figure Table of technical parameters 6...
Страница 19: ...Figure Connection to the heating system and hot water tank...
Страница 20: ...Figure Connection to the heating system and heat exchanger for the pool circuit...
Страница 21: ...Figure Connection to the heating system and storage tank for secondary water supply...
Страница 22: ...Figure Wiring diagram of NeoR heat pump technology...
Страница 24: ...8 Unauthorized connections to the heating system Figure Unauthorized connections to the heating system...
Страница 48: ...8 Hydraulic wiring diagram of the indoor unit Figure 8 Hydraulic diagram of the indoor unit 8...
Страница 49: ...8 Structural BOM Figure 8 Structural BOM...
Страница 50: ...8 Dimensions Figure 8 Dimensions...
Страница 51: ...8 Removing the cover Figure 8 Removing the cover...