ILDW-7090524-00D-31
15
MAC
(
32-39
)
: Rainbow slow speed mode-no time to remain
MAC
(
40-47
)
: Rainbow medium speed mode - no time to remain
MAC
(
48-55
)
: Rainbow fast speed mode - no time to remain
MAC
(
56-63
)
: Rainbow very slow mode - no time to remain
MAC
(
64-70
)
: Slow speed random colors
MAC
(
72-79
)
: Medium speed random color
MAC
(
80-87
)
: Fast speed random color
MAC
(
88-255
)
: When the value of MAC is between 8 and 87, the channel 3,4,5,7,8,9 is
invalid. The operating value is installed of red, green and blue. Other channel is valid.
Step12
:
Switch to submenu TM-H
(
0-23
),
The start value is 0 here, which is used to record
running hours.
Step13
:
Switch to submenu TM-M
(
0-23
),
The start value is 0 here, which is used to record
running minutes.
Step14
:
Switch to submenu TM-S
(
0-23
),
The start value is 0 here, which is used to record
running seconds.
Note
:
If you want to make it run, the value of TM-H
,
TM-M and TM-S can not be 0 at the
same time. Furthermore, if the white balance control is open, the six balanced value of RGB can
not be 0 at the same time.
Step15
:
Switch to submenu FD-H
(
0-59
),
The start value is 0 here, which is used to record
visional running hours.
Step16
:
Switch to submenu FD-H
(
0-59
),
The start value is 0 here, which is used to record
visional running minutes.
Step17
:
Switch to submenu FD-H
(
0-59
),
The start value is 0 here, which is used to record
visional running seconds.
Step18
:
Switch to submenu SCRUN, when the display shows ON. This indicates that the set can
run. When the display shows OFF, the parameter set is invalid.
Step19
:
Switch to submenu R1.The value ranges from 0 to 255.It is used to adjust the red
brightness of the second fixture. The value is 255 here.
Step20
:
Switch to submenu G1.The value ranges from 0 to 255.It is used to adjust the green
brightness of the second fixture. The value is 0 here.
Step21
:
Switch to submenu B1.The value ranges from 0 to 255.It is used to adjust the blue
brightness of the second fixture. The value is 0 here.
Step22
:
Switch to submenu DIM1.The value can not be 0.It is 255 now (the total RGB brightness of
the second fixture).
Step23
:
The first scene of the first program is finished. Then switch to submenu SCENE (1-10). At
first you select scene 2.Follwing the above step 4 to step 22, totaling 18 parameters. You can set the
quantity of scene (maximum: 10 minimum: 0) according to your own requirement.
Содержание VariFlood Duo