background image

 

CHAUVET, 3000 N 29

th

 Ct, Hollywood, FL 33020 U.S.A  

(800) 762-1084 

 (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com 

2006-07-14/15:25 

 

 

LED-RAIN36

USER MANUAL 

Содержание LED-RAIN36

Страница 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 07 14 15 25 LED RAIN36 USER MANUAL ...

Страница 2: ...DUCT OVERVIEW 5 SETUP 6 POWER 6 MOUNTING 6 OPERATING INSTRUCTIONS 7 MASTER SLAVE STAND ALONE MODE 7 Daisy Chain Connection 7 Built in Program Options 8 Manual Control Options 8 DMX CONTROL MODE 9 Setting the DMX address 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 RETURNS PROCEDURE 11 CLAIMS 11 DMX DIPSWITCH QUICK REFERENCE CHART 12 TECHNICAL SPECIFICATIONS 13 TECHNICAL SUP...

Страница 3: ...s Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or s...

Страница 4: ...TION Features CONTROL FEATURES 2 channel DMX 512 LED pinspot Dimmer Strobe FEATURES 86 white LEDs per surface Ultra bright LEDs Built in strobe program Low power consumption Up to 100 000 hour LED life span Master Slave mode OPTIONS Programmable Any universal DMX 512 controller DMX Channel Summary ...

Страница 5: ...LED RAIN36 User Manual 5 2006 07 14 15 25 DMX dipswitches DMX channel addressing DMX Connectors Fuse Power connection Hanging yoke Power link AC Voltage Switch Product Overview ...

Страница 6: ...a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Live L BLUE Neutral N YELLOW GREEN Earth EG Ground...

Страница 7: ...ficient and super bright white LEDs The LED RAIN36 can operate in Stand Alone Master Slave and via DMX 512 control utilizing 2 channels Master Slave Stand Alone Mode The Master Slave mode will allow you to link up to as many units you want in a daisy chain fashion In this mode the first unit in the daisy chain will automatically command all other units following 1 Connect all LED RAIN36 units in a...

Страница 8: ... adjusted by turning ON dipswitches 1 through 8 as illustrated next Dipswitch 10 must be set to OFF Manual Control Options DIPSWITCHES ON ADJUSTMENT PROGRAM FUNCTION 1 2 3 4 5 6 7 8 Light Intensity 0 100 Solid very narrow beam 9 8 9 7 9 6 9 5 9 4 9 3 9 2 9 1 9 Strobe Speed Min Max Strobing Only the number of the dipswitch listed in this column is turned ON all others remain OFF ...

Страница 9: ...e If this is your first time addressing a fixture using the DMX 512 control protocol than I suggest jumping to the Appendix Section and read the heading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each sw...

Страница 10: ... of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 wh...

Страница 11: ... return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be re...

Страница 12: ... 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 1...

Страница 13: ...Hz FUSE Main 20mm Glass 1A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 2 ORDERING INFORMATION LED RAIN36 LED RAIN36 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone ...

Отзывы: