background image

                           

ILDW-7090524-00D-31 

 

 

14

 Instruction

 

            Step1

When the display of the main menu shows HELLLO, the dot flicks. Then press UP/DOWN 

for a short second until the master is on.   

            Step2

Press MODE to switch to main menu and then switch to submenu PGRUN (OFF, 1 ,2, 3) 

OFF means it does not work

1 represents that it operates in the first program. 2 represents that it 

operates in the second program. 3 represents that it operates in the third program.   

            Step3

Press MODE for a short time and exit to main menu. Switch to PGSET, and then press 

MODE for a longer time until the display shows PROG. The value of PROG ranges from 1 to 3. 1 stands 

for the program which needs to be edited is program1. 2 stands for the program which needs to be 

edited is program2. 3 stands for the program which needs to be edited is program3.Take the PROG=1 

as example, every program can used to set 10 scenes the most, 1 the least each of which needs to set 

18 parameters

Detailed as below: 

          Step4

  Switch to submenu SCENE (1-10), at first you set 1. 

          Step5

  Switch to submenu FIXT. = ALL

,(

about the FIXT has been introduced above

          Step6

 Switch to submenu SHUTT

0-255

. You set it to 80.You can set the below value 

according to your own demand.   

              Shutt (0-255): detailed parameter as below 

              Shutt

0-3

:    all leds are off

 

              Shutt

4-6

:  on

 

Shutt

7-59

: strobe (20~1Hz) 

 

Shutt

60-69

: Visional Strobe on

 

Shutt

70-78

: Visional Strobe off 

Shutt

79-87

: Randomly strobe (from fast to slow) 

Shutt

88-255

: On

 

 

          Step7

 Switch to submenu DIM0.This value cannot be set 0. The value is 255(the total 

brightness of the first lamp).   

          Step8

 Switch to submenu R0.The value ranges from 0 to 255.It is used to adjust the red 

brightness of the first fixture. The value is 0 here.   

Step9

 Switch to submenu G0.The value ranges from 0 to 255.It is used to adjust the green 

brightness of the first fixture. The value is 255 here.   

Step10

Switch to submenu B0.The value ranges from 0 to 255.It is used to adjust the blue 

brightness of the first fixture. The value is 255 here.   

Step11

Switch to submenu MAC, the value of which ranges from 0 to 255.When the value of 

MAC is between 8 and 87, the setting value of the R0

G0

B0

R1

G1

B1 is valid. Otherwise it 

is the value installed. 

              MAC

0-7

: When the value of MAC is 0-7 and 88-255, all channels are valid

.

   

              MAC

8-15

: Rainbow slow mode-5 seconds 

MAC

16-23

: Rainbow medium speed mode-5 seconds 

MAC

24-31

: Rainbow fast speed mode-5seconds 

Содержание VariFlood Duo

Страница 1: ...ILDW 7090524 00D 31 1 High Power LED Washer 45 3in1 Plus 45 3W totaling 90 PCS User Manual Neo Neon LED Lighting International Ltd ...

Страница 2: ...ion 4 5 Safety Warning 4 6 Installation 5 6 7 Operation Instruction 6 Panel Instruction 6 Menu 6 9 Function 9 DMX Mode Linking Mode 9 12 Test Mode 13 Auto Mode 14 16 Timing Mode 16 17 Temperature protection Mode 17 8 Operation Instruction 17 Troubleshooting 17 Clearance and Maintenance 17 18 9 Sketch Map of hand wheel installation 19 ...

Страница 3: ...e brightness of the digital displaying tube The safeguarding function of over heat Auto Test Mode Record the running time of the different colorful LED Record the total running time of the fixture Can edit three pieces of programs 10 acts of each program for maximum Can edit 36 pieces of time events each event can randomly install the running start and end time of the included programs All above a...

Страница 4: ...the manufacture z The operating temperature should be not above 40 and not below 20 If there are some problems please ask the professional for repair We change our packaging of four hand wheels used for position into four smaller ones for safety when packaging and transportation The six hand wheels will be packaged and complimented away with the lamp If the customer needs them we will change back ...

Страница 5: ...ing the power supply and then take out the power supply crust The effect picture is illustrated as below ⅳ When the crust of the power supply is pulled out there are four isosceles slots under the bracket of the fixture You use bolt through isosceles aperture to link and position the object and install the crust of the power supply The final effect picture is illustrated as below ...

Страница 6: ...p Menu instruction ⅱ No Title Content Content of main menu Change the content Submen u Submenu options How to enter submenu functions 1 Set DMX signal channels A001 Press enter Press Up enter Set up the DMX starting channels Rblac Gblac 2 Adjust White Balance balance Bblac Press enter for 2 3secon ds Set up RGB parameter ...

Страница 7: ...LI Press enter Press Up enter Adjust the positive or opposite display 10 DMX delay Dmxdl Press enter Press Up enter Set up the period for the wash with no DMX signal YEAR M D H M 11 Time time WEEK Press enter for 2 3seco Set up the inner time of the wash 12 Factory Parameters FACT Recover the parameter 13 Previous Parameters PREV Recover the parameter previously set up Red Green Bule CTC All shutt...

Страница 8: ...nter for 2 3secon ds Edit the programmin g of the wash event program day start end 21 Schedule Schedu enable Press enter for 2 3secon ds Edit the timing ⅲ Function Instruction 1 Reset after it is connected to power supply and below are steps to control RGB light When it is connected to the power supply the system is initialized The reset interface of the display shows as below drawing When the dis...

Страница 9: ...lay does not flick Then press UP or DOWN to enter main menu MASTER when you press MODE for a short second The display flicks and press UP or DOWN until the display shows OFF namely entering into DMX mode 2 2 DMX Connector DMX male connector PIN1 GND ground wire PIN2 COLD signal negative PIN3 HOT signal positive 2 3 DMX Link Chart The distribution under the DMX control Chann el Name Value Function ...

Страница 10: ... Rainbow slow mode 5 seconds 16 23 Rainbow medium speed mode 5 seconds 24 31 Rainbow fast speed mode 5seconds 32 39 Rainbow slow speed mode no time to remain 40 47 Rainbow medium speed mode no time to i 48 55 Rainbow fast speed mode no time to remain 56 63 Rainbow very slow mode no time to remain 64 70 Slow speed random colors 71 The installed color function 72 79 Medium speed random color 11 MAC ...

Страница 11: ...ess UP DOWM for a short second until the display switch to the main menu SLAVID Then press MODE for a short time It will show submenu XX 01 39 flicking Press UP DOWN to change the ID of this product After selection press MODE for a short time the display will return to main menu SLAVID Note The setting of main menu SLAVID is valid under auto and DMX mode If you want to know more explicitly about i...

Страница 12: ...ter under the condition that the Fixt value of the slave fixture is SLV01 When the display of the host computer shows Fixt SLV02 XX 01 29 the master runs normally The slave fixture will receive data from the master under the condition that the Fixt value of the slave fixture is SLV02 The rest will be deduced by analogy ⅳ TSET Mode Instruction Step1 When the display shows the main menu HELLO the do...

Страница 13: ...ess MODE for a short second until the submenu ALL does not flick when all LEDs are off Step7 Press UP for a short time the display showing SHUTT does not flick Then press MODE for a short time until the submenu SHUTT flick when all LEDs of the two fixtures begin to strobe Then press MODE for a short second until the submenu ALL does not flick when all LEDs are off Step8 Press UP for a short time t...

Страница 14: ...p6 Switch to submenu SHUTT 0 255 You set it to 80 You can set the below value according to your own demand Shutt 0 255 detailed parameter as below Shutt 0 3 all leds are off Shutt 4 6 on Shutt 7 59 strobe 20 1Hz Shutt 60 69 Visional Strobe on Shutt 70 78 Visional Strobe off Shutt 79 87 Randomly strobe from fast to slow Shutt 88 255 On Step7 Switch to submenu DIM0 This value cannot be set 0 The val...

Страница 15: ... start value is 0 here which is used to record visional running hours Step16 Switch to submenu FD H 0 59 The start value is 0 here which is used to record visional running minutes Step17 Switch to submenu FD H 0 59 The start value is 0 here which is used to record visional running seconds Step18 Switch to submenu SCRUN when the display shows ON This indicates that the set can run When the display ...

Страница 16: ... that this event can only run on Monday DAY TUE indicates that this event can only run on Thursday DAY WED indicates that this event can only run on Wednesday DAY THU indicates that this event can only run on Thursday DAY FRI indicates that this event can only run on Friday DAY SAT indicates that this event can only run on Saturday DAY SUN indicates that this event can only run on Sunday DAY ALL i...

Страница 17: ...the controller Whether it is in Master mode Set it in slave mode under DMX Mode Wrong address Check the address and set uniformly There is a piece of fixture whose connector can not work normally After pulling the input and output signal cable out of the fixture and connect each other directly Then check whether there is a problem with the fixture If it works well after connecting it proves that t...

Страница 18: ...onfirm the light to show itself under the best situation which is necessary I The cleaning of the fixture II The cleaning maintaining of the lens To ensure the optimum effect of the fixture please clean each lens or the reflecting configuration Please use the soft cotton cloth with little lotion to clean lens and protect the lens from damage III The regular examine of the cables Check the connecti...

Страница 19: ...090524 00D 21 ILDW 7090523 00D 21 25 WHITE ILDW 7090524 00D 31 ILDW 7090523 00D 31 BLACK ILDW 7090544 00D 11 ILDW 7090543 00D 11 GREY ILDW 7090544 00D 21 ILDW 7090543 00D 21 40 WHITE ILDW 7090544 00D 31 ILDW 7090543 00D 31 BLACK ILDW 70905D4 00D 11 ILDW 70905D3 00D 11 GREY ILDW 70905D4 00D 21 ILDW 70905D3 00D 21 10 25 WHITE ILDW 70905D4 00D 31 ILDW 70905D3 00D 31 BLACK ILDW 70905D4 00D 11 ILDW 709...

Страница 20: ...ILDW 7090524 00D 31 20 ...

Отзывы: