ILDW-7090524-00D-31
17
. Daily Maintenance
Ⅵ
Trouble Shooting
Trouble Reasons
Trouble
Shooting
No power supply
Check whether the power
supply is turned on and the
power cable is connected
well.
One or many of fixtures
does not work
The power supply is burnt.
Turn of the power supply.
Then change into the same
type of power supply.
If the power supply is burnt
continuously, there may
have some problems with
the power cable. Please ask
professional staff to repair.
The data connecting is
wrong or uncompleted
Check, repair or change the
data cable and check
whether it is connected well
and the signal input of the
first fixture is connected
with the output of the
controller
Whether it is in Master
mode
Set it in slave mode under
DMX Mode
Wrong address
Check the address and set
uniformly
There is a piece of fixture
whose connector can not
work normally
After pulling the input and
output signal cable out of
the fixture and connect
each other directly. Then
check whether there is a
problem with the fixture. If it
works well after connecting,
it proves that there is a
problem with the signal
connector of the fixture.
According to the method---
trouble shooting, then select
the broken fixture and ask
the professional staff to
repair.
The replacement is normal
but the controller can not
work well or there is no
feedback
The signal output of the
controller is not matched with
the connector of the signal
receiving(PINS2—3 is wrong)
Dial the polarity switch of
the controller to “PHASE”,
and exchange the address
of PIN2—3