N1500i FACS Manual
47
Part No. 729-110-053 V.1.03
© 2018 Nelson Stud Welding, Inc. All rights reserved.
F
code
Description
Possible Values
Default
Unit
Notes
F49
Pulse Weld Enable
OFF ON
OFF
X
Enable this to use pulse welding, where the main current
pulses to a high and low current setting at variable time
settings per F codes F50-F52.
F50
Pulse Weld
High Current
50 to MAX_CURRENT
800
Amps
This is the current used for as the lower of the two currents
during the weld. (The front panel current setting will be
the high current). MAX_CURRENT is that maximum
current the unit can deliver given the power conditions
and model.
F51
Pulse Weld High Time
5 to 10
5
ms
This is the time the weld will deliver the front panel
current (F50 current).
F52
Pulse Weld Low Time
20 to 25
25
ms
This is the time the weld will deliver the low current.
F68
Input Board Gain
95-105
100
%
Factory Only
F69
Input Board Offset
700-1300
1000
X
Factory Only