1. Connection and Installation
1.1 Installation Precautions
The welder must be installed on a horizontal, vibration-free and non-slip floor
space. The load-carrying capacity of the floor space should be at least double
the weight of the welder.
When working in elevated locations, such as bridges, ladders or platforms the
N1500i must be secured against the risk of falling.
The N1500i must be adequately protected against the intrusion of liquids. It may
not be installed on liquid-bearing pipelines.
In order to guarantee unimpeded temperature exchange with the environment, a
minimum clearance of 1 m (39.4 inch) to existing heat sources must be
observed.
Attention must be paid to the fact that the ventilation slits on the unit casing are
kept free.
1.2 Connection
With the exception of the input power cable all the connecting elements are
arranged in a functional manner on the front plate of the N1500i.