N1500i FACS Manual
77
Part No. 729-110-053 V.1.03
© 2018 Nelson Stud Welding, Inc. All rights reserved.
Lift height is too high or plunge depth (stick-out) is too much. Perform a
lift test by pressing the gun against an insulated surface. Air lift test will
not fully test the lift capability of the welder gun coil circuit.
Workpiece vibration is snuffing out the pilot arc.
8.3.10 E010 Capacitor Voltage Could Not Be
Read
Fatal, meaning you have to power down to continue welding
>> No
Acknowledge, meaning the error will exist as long as the unit
is powered on. (Note, welding can continue while the error
exists)
>> No
Description:
The voltage-to-frequency signals as provided by the switch boards to
the FACS input board are not within a 'window' defined by the control
board (indicating that they are invalid or caused by noise on the signal
line).
Likely problems or items to check - in order from most likely to least
likely:
1. Inspect V-F wiring from switch board to FACS input
board. Keep wiring away from high power wires.
2. Eliminate possible sources of external electrical noise on
the same circuit as this welder.
3. Replace switch board.
4. Replace FACS input board.
8.3.11 E011 Unit Too Hot-Please Wait
Fatal, meaning you have to power down to continue welding
>> No
Acknowledge, meaning the error will exist as long as the unit
is powered on. (Note, welding can continue while the error
exists)
>> No
E010
E011