Error
Number
Error Display
What this really means
Fatal
– meaning you
have to power down
to reset. Otherwise,
you weld again to
reset.
Likely problem
E017
PILOT ARC BLEW OUT DU-
RING PILOT STAGE
Arc voltage was detected to have
been higher than 60V after the gun
lifted, which is too high to still have an
arc.
Debris on the work material.
E018
WARNING - DROP TIME IS
TOO LONG FOR SHORT CYC-
LE
The configurations of the drop time (F31)
and the front panel time make it such that
the pilot arc supply must be on for more
than 40ms. The maximum time the pilot
arc will stay on is 40ms, so it is possible
the arc will go out before the main arc
starts. For consistent welds, reconfigure
the drop time and\or front panel time to
satisfy the equation
F code \ Front panel configuration
E019
MACHINE TYPE UNDEFINED
Jumper plug in user interface is not
present
X
ADDITIONAL WARNING -
WAIT ON UPPER DISPLAY
AND CYCLE OR CAP ON
LOWER DISPLAY
1.
Weld duty cycle is exceeded
2.
Switch board out of calibration
3.
Switch board malfunction
X
1 of 3 reasons.
-See troubleshooting-