N1500i FACS Manual
79
Part No. 729-110-053 V.1.03
© 2018 Nelson Stud Welding, Inc. All rights reserved.
Likely problems or items to check - in order from most likely to least likely:
1.
Gun lift setting is causing too many or too large of material transfers,
which are shorting the arc for over 100ms. If this happens, the lift
should be adjusted to overcome the transfers. If the unit were to
continue to deliver current through a short.
2.
Determine if it is an internal problem by trying different types of studs
and gun settings. If the unit consistently reports this error, it is internal.
3.
Inspect wiring from FACS input board J24 pins 11 and 12 to the weld
outputs. Make sure the control can sense the voltage appropriately.
4.
Replace control board.
8.3.12 E013 Weld Failed - Out of Tolerance
Fatal, meaning you have to power down to continue welding
>> No
Acknowledge, meaning the error will exist as long as the unit is powered
on. (Note, welding can continue while the error exists)
>> No
Description:
If the unit is configured to compare each weld results (Actual current, voltage, time,
etc.) to a given weld 'target', it will display this error when the last weld is out of the
configured tolerance range. Change weld setup as appropriate, set a new target,
or disable this error as necessary.
Likely problems or items to check - in order from most likely to least likely:
1.
Change the weld setup as appropriate.
2.
Configure new target. To do this, select F32 and hold the lock
button.
3.
Adjust tolerance (weld energy F35 or drop time F34)
E013