N1500i FACS Manual
46
Part No. 729-110-053 V.1.03
© 2018 Nelson Stud Welding, Inc. All rights reserved.
F
code
Description
Possible Values
Default
Unit
Notes
F32
Weld Results
I= Current (Amps)
V= Voltage (Volts)
tM=Main current time (ms)
E= Energy (Joules)
tD=Drop Time (ms)
tP=Pilot Time (ms)
Pass\Fail indicator
NA
x
This F code gives information about the last weld. To save
these weld results as the target (for weld comparison),
press and hold the ‘Lock’ key. To clear targets, exit to
time\current mode and click the 'Lock' key + the desired
preset key at the same time. For the main preset (no
preset), use the 'Lock' key + the time-down arrow key.
F33
Disable Welding on
Weld Error
OFF ON
OFF
X
Turn this on to disable welding when a weld error occurs
or when a weld is out of specified weld energy\drop time
range. Flashes ‘WELD ERROR!’ and requires a password
to continue. Password is 123456 by default, but can be
changed to any number up to 9 digits. Use lock mode 2 or
3 to set the password.
F34
Drop Time Tolerance
0 to 1000
100
ms
This defines the tolerance allowed from target weld drop
time for determining good/bad weld.
F35
Weld Energy Tolerance
1 to 20
10
%
This defines the tolerance allowed from target weld
energy for determining good/bad weld.
F36
Process Monitor Error
Code on Failed Weld
OFF ON
OFF
X
When enabled, an error code is given when the weld is out
of tolerance.
F43
Diagnostic Data
# Phases, PWM AVG,
ABORT code, Capacitor
imbalance, or Duty Cycle
# Phases
X
This gives extra diagnostic data after each weld. If the
power unit is at the maximum output in voltage and
current, PWM AVG will be 100%.
F45
Output Board
Calibration Offset
700 to 1300
1000
X
Used by manufacturing. Do not change.