7.1.1 Notes on which F codes change automatically
4-Wire Gun Interfaces
Action
Result
F31 - Drop TIme
F2 - Plunge
Short Circuit
On-Time
F44 - Preset Bank
F30 - Short
Cycle Enable
weld
max
weld
min
Other Notes
F30
Short Cycle
Mode = ON
7ms
20ms
2 (Short Cycle
Values)
-
100ms
5ms
Limits Stud Expert studs, Limits
presets to 100ms max weld time.
F30
Short Cycle
Mode = OFF
12ms
20ms
1 (Drawn Arc
Metric Values)
-
1000ms
100ms
Limits Stud Expert studs, Limits
presets to 100ms min weld time.
F12
Sud Feed
Enable = ON
-
-
-
ON
-
-
2-Wire Gun Interfaces
Action
Result
F31 - Drop TIme
F2 - Plunge
Short Circuit
On-Time
F44 - Preset Bank
F30 - Short
Cycle Enable
weld
max
weld
min
Other Notes
F30
Short Cycle
Mode = ON
35ms
20ms
2 (Short Cycle
Values)
-
100ms
5ms
Limits Stud Expert studs, Limits
presets to 100ms max weld time.
F30
Short Cycle
Mode = OFF
35ms
100ms
0 (Drawn Arc
English Values)
-
1000ms
100ms
Limits Stud Expert studs, Limits
presets to 100ms min weld time.
F12
Sud Feed
Enable = ON
-
-
-
ON
-
-