Stud welding unit N1500i
As of: Aug 12.2021
Manual part number: BE 1221
56
Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
6.3.8 Parameters for short - cycle procedure
Note!
The following parameters are only starting points (guide values)
which must be adjusted to specific application conditions (base
material, work piece surface condition, weld position, gun type, weld
circuit inductance and grounding etc.). It is recommended to perform
weld robustness test (current- time tolerance graph) using the values
below as center points to determine optimum welding parameters for
the application..
Preset
Stud Size
∅
Current
(Amps)
Time
(msec)
Lift
(mm)
Plunge
(mm)
1
3/16”
5mm
300
15
.062
.125
2
1/4”
6mm
400
17
.062
.125
3
5/16”
8mm
450
25
.062
.125
4
3/8”
10mm
500
33
.062
.125
5
7/16”
11mm
625
42
.062
.125
6
1/2”
13mm
750
55
.062
.125
7
5/8”
16mm
1100
67
.093
.187
8
3/4”
19mm
1400
84
.093
.187
9
3/4”
19mm
1400
84
.093
.187
0
3/4”
19mm
1400
84
.093
.187
Rule of thumb for the parameters for the Short - Cycle - Procedure
•
Ι
[A]
≅
100*
φ
•
t [ms]
≅ 4
*
φ
φ
is in mm units.