Page 5
Doc. no#: 310-0100-004-001 R200 Manual
Technical description
Technical details:
RS-232
Baud: 1200-115200
Data bit:7/8
Parity: none, even, odd
Stop bit: 1/1,5/2
IR
Transmit 381 Hz – 500 KHz
LAN
10/100 MBit
Input
Sence low < 1 VDC
Sence high > 4 VDC
Output
Open drain
Max voltage: 24 VDC
Max current: 0,5 A
Power
12VDC (110-230VAC Adapter included)
USB
The USB port can only be used to program the Neets Control – SieRRa from the
Neets Project designer software. It cannot be used to control any devices what
so ever.
From the USB you can also power the system. This is to be used in programming
situations, so you do not have to connect 12VDC to the unit to program it.
The USB connector needed to connect to the Neets Control – SieRRa is of the type
mini USB B 5P. You can either buy this cable from Neets or via the web (buy a USB A
to Mini USB B 5P). The cable type is also widely used for MID device and compact
cameras and so on.
RS-232 Port
The onboard RS-232 port (TX-1 and RX-1) is used for two way
communication. This port is used for the device you want to use reply on
(e.g. your projector). It can also be used for uploading settings to the unit
(be aware that this is the most slow way to do this).
To connect the Neets Control - SieRRa you must wire the RS-232 cable as
shown here to the right. This is a Female 9 pin SUB-D connector that will fit
into a standard computer RS-232 port, or any USB to RS-232 converter.
EU version
DK version
Содержание SieRRa DK