
FlexPAK 800/1000 DX
EN
28
Table 3-2: Technical data FlexPAK 1000 DX
FlexPAK 1000 DX
Effect
18.5 kW (25 hp)
18.5 kW (25 hp)
21.5 kW (29 hp)
Mains voltage/frequency
230 V±10%/50–60 Hz
400 V±10%/50–60 Hz
460 V±10%/50–60 Hz
Maximum flow
1,300 m
3
/h (765 cfm)
1,300 m
3
/h (765 cfm)
1,300 m
3
/h (765 cfm)
Flow at -15 kPa
1000 m
3
/h (588 cfm)
1000 m
3
/h (588 cfm)
1000 m
3
/h (588 cfm)
Maximum vacuum
-20 kPa (-2.9 PSI)
-20 kPa (-2.9 PSI)
-20 kPa (-2.9 PSI)
Filter area
6 m
2
(64.5 sqft)
6 m
2
(64.5 sqft)
6 m
2
(64.5 sqft)
Weight
439 kg (968 lb)
439 kg (968 lb)
439 kg (968 lb)
Inlet/outlet diameter
150/160 mm (7.87/6.29")
150/160 mm (7.87/6.29")
150/160 mm (7.87/6.29")
Sound level
70 dB(A)
70 dB(A)
70 dB(A)
Filtration efficiency*
Dust class L
Dust class L
Dust class L
Maximum ambient temperature
-10 – +40 °C (14–104 °F)
-10 – +40 °C (14–104 °F)
-10 – +40 °C (14–104 °F)
Relative humidity
Max. 85%
Max. 85%
Max. 85%
Compressed air
6–7 bar (87–102 PSI)
6–7 bar (87–102 PSI)
6–7 bar (87–102 PSI)
Material recycling
93.6% per weight
93.6% per weight
93.6% per weight
Control Filter area
1x12 m² (1x129 sqft)
1x12 m² (1x129 sqft)
1x12 m² (1x129 sqft)
Control Filter material
Polyester
Polyester
Polyester
* According to DIN EN/IEC 60335-2-69.
3.6
Fuses
Table 3-3: Fuses
Fuse
Size
Type
Main fuse F1, 230 V
65 A
Slow mains fuses
Main fuse F1, 400 V
35 A
Slow mains fuses
Main fuse F1, 460 V
40 A
Slow mains fuses
Transformer, primary fuse F2 and F3
6 A
Slow fuses, 10.3×38
Transformer, secondary protection
PTC resistor
F4
50 mA
Fast, 5×20
F5
1 A
Slow, 5×20
3.7
Main components
Figures 4A, 4B and 4C show the main components of the unit:
1.
Collector bin, see figure 4A.
NOTE!
Never use the unit without an antistatic plastic bag. Use Nederman original bags
only.
2.
Dust extractor, see figure 4A.
3.
Textile filter bags, see figure 4A.
4.
Filter holder, see figure 4A.
5.
Filter Cleaning Valve (FCV), see figure 4A.
6.
Connection duct from the dust extractor to the inlet silencer, see figure 4A.
7.
Start and control unit, see figures 4A and 4B.
8.
Control panel, see figures 4A and 4B.
9.
Frequency converter, see figures 4A and 4B.
10.
Emergency switch, see figures 4A and 4B.
11.
Frequency converter cooling air filter, see figures 4A and 4B.
12.
Cooling valve, see figures 4A and 4B.
13.
High pressure side channel fan, with pump characteristic, see figures 4A and 4B.
14.
PT100 sensor, see figure 4B.
Содержание FlexPAK 1000 DX
Страница 2: ...FlexPAK 800 1000 DX 2 ...
Страница 9: ...FlexPAK 800 1000 DX 9 A B C 4A 3 13 12 10 9 7 8 2 1 3 4 6 5 11 ...
Страница 10: ...FlexPAK 800 1000 DX 10 4C 4B 11 7 8 9 12 13 16 15 14 17 18 19 20 21 10 ...
Страница 13: ...FlexPAK 800 1000 DX 13 9 10 1643 1mm 65 662 1mm 26 2 1771 4 1mm 70 Ø13mm 4 1 2 3 6 7 8 10 9 11 5 1 ...
Страница 14: ...FlexPAK 800 1000 DX 14 11 12 14 13 ...
Страница 15: ...FlexPAK 800 1000 DX 15 1 5m 59 A B C 16 17 15 Min 2 1m 83 A A A A C ...
Страница 16: ...FlexPAK 800 1000 DX 16 18 Circuit Diagram FlexPAK 800 1000 Loggo PLC DU1 and Frequency Converter UE1 ...
Страница 17: ...FlexPAK 800 1000 DX 17 19 Circuit Diagram FlexPAK 800 1000 Digital I O Extension Modul DU2 ...
Страница 18: ...FlexPAK 800 1000 DX 18 20 Circuit Diagram FlexPAK 800 1000 PT100 Extension Module DU3 ...
Страница 19: ...FlexPAK 800 1000 DX 19 21 Circuit Diagram FlexPAK 800 1000 Layout Terminal X1 and Frequency Converter UE1 ...
Страница 20: ...FlexPAK 800 1000 DX 20 22 ...
Страница 545: ...www nederman com ...