19 NED
XCM4040SAT4 UME-0002-04
Set the LVDS, Channel Link receiver side to 100
ohm termination.
Do not make the driver side of LVDS open but set the logic to H or L, even if
not used.
Figure 3-3-2 Circuit of LVDS
The camera has 26-pin MDR connectors for control signals of Camera Link,
data signals and serial communications. The camera also has a 4-pin
HIROSE connector for power supply.
Figure 3-3-3 Camera Link Connector
Half pitch (miniature half ribbon) shape
Locking screw (UNC #4-40) type
+
-
100Ω
+
-
Driver
Receiver
H or L
1
14
2
15
3
16
11
24
12
25
13
26