33 NED
XCM4040SAT4 UME-0002-04
the camera always checks the memory status. If the data is not within the
designated range due to a malfunction or other type of trouble, the memory
will be automatically reset to the factory settings.
If the camera power is disconnected while rewriting the memory, the
whole data saved in the memory will be deleted.
As it takes several seconds to rewrite the memory, do not disconnect power
supply before receiving the answer from the camera.
Commands for rewriting the memory are as follows.
Reset to factory settings
(rst)
Store present setup data in memory
(sav)
Store pixel correction data in memory
(wht)
When changing the factory setting exposure mode, be sure to send the
control input signal (CC1). If you do not send CC1 or sending control input
signals are out of the designated range, you cannot get images and cannot
change the settings. See 4.8.2 and 4.8.3.
Table 4-5-1 Camera Operation Mode and Control Input
Camera operation mode
(Exposure mode)
Control input
(From frame grabber board)
Free Run (Programmable time setting)
(
Factory Setting
)
Not in use
Ext Edge (External trigger edge +
Programmable time setting
)
External trigger (CC1) is required
Ext Level (External trigger level time
setting)
External trigger (CC1) is required
4.6 Serial Communication Settings
Serial communication is performed through the Camera Link Interface
Table 4-6-1 shows serial communication settings.
Table 4-6-1 Serial Communication Settings
Parameter Items
Setup Value
Communication Speed (Baud rate)
9600bps
Data Length
8bit
Parity Bit
None
Stop bit
1bit
Flow Control
None