30 NED
XCM4040SAT4 UME-0002-04
wht
CR
>OK
>wht
4.2.13 Setting Pixel Correction
Sets pixel correction.
Format 3
CMD VAL1 VAL2
CR
CMD shc
VAL1
0,1,2 (0:Correction OFF /1:Factory white correction
/2:Arbitrary white correction, Correction level (10bit))
VAL2
0 to 1023 (Setting correction level:10bit)
<Example>
shc 1 900 CR (for Factory white correction, Correction level 900)
>OK
>shc 1,900
4.2.14 Setting Exposure Time - Readout Time
Prolongs the line period without changing the exposure time.
Format 2
CMD VAL1 CR
CMD pad
VAL 1
0 to 50 (0-40960
μ
s)
<Example>
pad
□
10 CR
>OK
>pad 10
The increment of the line period depends on
the exposure time setting
command VAL1 in “int”. For example, if VAL1 (in “int”)=1 and VAL1 (in
“pad”)=1, the increment is 12.5ns x 2 x 16 x 2=0.8
μ
s.
If VAL1 (in “int”) = 3 and
VAL1 (in “pad”)=1, the increment is 12.5ns x 2 x 16 x (2 x 2 x 2)=3.2
μ
s. And
if
VAL1 (in “int”)=5 and VAL1 (in “pad”)=1, the increment is 12.5ns x 2 x 16 x (2 x
2 x 2 x 2 x 2)= 12.8
μ
s.