37 NED
XCM4040SAT4 UME-0002-04
4.8.2 External Trigger Exposure Mode (Trigger Edge)
In external trigger exposure mode
(Trigger Edge)
, the exposure time is
determined by the setting for the line period parameter, each exposure starts
with the rising edge and the line period is determined by the time from rising
edge to rising edge of the internal control signal. The range of programmable
exposure time, the timing chart of the exposure and the readout are shown
below.
Table 4-8-2-1 Programmable Exposure Time
4040SAT4
P
Programmable exposure time
24.4
-
838,042
r
Readout time
25.6
a
Trigger pulse H time
≧
1.6
b
Trigger pulse L time
≧
2.4
c
Trigger pulse cycle
≧
26.8
(unit:μs)
Exposure
Readout
(1)
(1)
(2)
(2)
Trigger
(1)
(2)
(3)
(3)
(CC1)
a
b
p
r
c
Figure 4-8-2-1 External Trigger (Trigger Edge) Exposure Mode
The data of Exposure (1) is read out at Readout (1)