3-356
NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE TITLE:
SYSTEM TIMER DATA
41
Y=1
Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
1
09
Delayed Ringing
Timer
NONE
01
02
03 ..................................................20
2048 ms.
10240 ms. 2048 4096 6144 .............................................40960
11
Switch Control Screen
of LCD Pattern A/B
[North America
Only]
NONE
01
–
LCD
Control
Pattern B
(Normal)
LCD
Control
Pattern A
20
On-Hook Detect
Timer
NONE
01 02 03 .........................................................60
20 ms.
700 ms.
20 40 60 .......................................................1200
21
Momentary Open
Controlled Timer
NONE
01 02 03 .........................................................40
50 ms.
700 ms.
(Momen-
tary
Reverse)/
800 ms.
(discon-
nect)
20 40 60 .......................................................2000
22
SLT hook flash Detect
minimum timer
[8300R4]
NONE
01 02 03 .........................................................60
20 ms.
105 ms.
20 40 60 .......................................................1200
23
SLT hook flash
bounce guard timer
[8300R7]
NONE
01 02 03 .........................................................60
20 ms.
400 ms.
20 40 60 .......................................................1200
Continued on next page
BLADE RESET
BLADE RESET
BLADE RESET
JANUARY/31/2012
CM41
Содержание SV8300
Страница 1: ...Command Manual NWA 033623 001 ISSUE 8 1 ...
Страница 8: ...vi NWA 033623 001 Rev 8 1 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 772: ...3 716 NWA 033623 001 Rev 8 1 91ch3008 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...
Страница 804: ...A 32 NWA 033623 001 Rev 8 1 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...